Home > Iowa Academy of Science > Journals & Newsletters > Proceedings of the Iowa Academy of Science > Volume 46 (1939) > Annual Issue
Document Type
Research
Abstract
A discussion is given of the construction and use of thermocouples as wet and dry bulb hygrometers for measuring the vapor pressure of water in small spaces. Experiments for determining the effect of thermocouple form, air velocity, and other factors affecting the reading of the instrument are described.
Publication Date
1939
Journal Title
Proceedings of the Iowa Academy of Science
Volume
46
Issue
1
First Page
270
Last Page
270
Copyright
©1939 Iowa Academy of Science, Inc.
Language
en
File Format
application/pdf
Recommended Citation
Anderson, C. G.
(1939)
"Measurement of Relative Humidity by Menas of Thermocouples,"
Proceedings of the Iowa Academy of Science, 46(1), 270-270.