The following values have been reported for the specific conductance of liquid hydrogen sulphide.

0.1x10-6 ohm-1 cm3 - a-c method - Steel, Mcintosh & Archibald;

less than 4x10-7 ohm-1 cm3 - d.c. method - Magri;

1x10-11 ohm-1 cm3 - d.c. method - Quam & Wilkinson;

3.7x10-11 ohm-1 cm3 - d.c. method - Satwaleker, Butler & Wilkinson.